Normally Open 3-Way Piloted Valve

The F-5700 N.O. 3-Way Pressure Piloted Valve has an adjustable pressure pilot setpoint; the sensing pressure range is 0.5 to 100 PSI. Maximum signal pressure is 100 PSI.

CHF 122.45 (excl. VAT)

Delivery time: 2 - 4 weeks
Contact us for shorter delivery times Art.-Nr.: N/A Categories: ,

The F-5700 valve is available Normally Open, the sensing pressure range is 0.5 to 100 PSI. Maximum signal pressure is 100 PSI. The Normally Open valve senses the adjusted pressure setpoint and turns the valve output off. Four mounting styles are available: Flush Mount, Manifold Mount, Panel Mount, and Pipe Thread Mount. The Flush Mount has 0.125″ diameter mounting holes for mounting on a flat surface. The Manifold Mount is designed to mount directly on pneumatic circuit boards or manifold subplates; a Buna-N o-ring is supplied. The Panel Mount has a unique thread that goes from 1/8-27 tapered pipe thread to 1/8-27 straight pipe thread; a mounting nut is supplied. The Pipe Thread Mount has 1/8-27 tapered pipe threads. The pilot input is furnished with a B80 Barb, 10-32 Barbed Fitting for 1/16” I.D. tubing. The output has instant push in fittings for 5/32 O.D. tubing.

FEATURES

  • Adjustable pressure pilot setpoint
  • Sense pressure between 0.5 to 100 PSI
  • Normally Open

SPECIFICATIONS

Operating Speed: Activate or release in 65 milliseconds
Signal Pressure: 6.89 bar (100 PSI maximum)
Pilot Adjustment: 0.34 – 6.89 bar (0.5 to 100 PSI) +/- 0.5 tolerance on the initial starting pressure
Valve Pressure Range: 1.5 – 8 bar (22 to 116 PSI)
Temperature Limits: 5 to 48 °C (40 to 120 °F)

MATERIALS

Housing: Polysulfone
Diaphragm: Polyurethane
Spring: Stainless Steel or Music Wire

PORT CONNECTIONS

Pilot Input:
B80: 10-32 UNF Barbed Fitting for Ø1.6 mm (1/16″) I.D. tubing
B85: 10-32 UNF Barbed Fitting for Ø3.2 mm (1/8″) I.D. tubing
B86: 10-32 UNF Barbed Fitting for Ø4.3 mm (0.170″) I.D. tubing
Valve Input & Output: Instant push-in fittings for Ø2.4 mm (3/32″) I.D. x Ø3.98 mm (5/32″) O.D. tubing (4 mm o.d. tubing)

MOUNTING

Flush Mount: 0.125″ diameter mounting hole; use No. 4 self-tapping or 5-40 screw
Manifold Mount: Two 0.125″ diameter mounting holes; use No. 4 self-tapping or 5-40 screw (A Buna-N o-ring is supplied)
Panel Mount: External 1/8-27 NPT to 1/8-27 NPS, internal threads are 10-32 UNF. Ø11.11 mm (7/16″) diameter mounting hole is required. (A mounting nut is supplied)
Pipe Thread Mount: 1/8-27 male tapered pipe threads, internal threads are 10-32 UNF

Adjustment Range

100 – Adjustable 0.03 – 6.9 bar (0.5 – 100 PSI), 15 – Adjustable 0.03 – 1 bar (0.5 – 15 PSI), 30 – Adjustable 0.03 – 2.1 bar (0.5 – 30 PSI), 60 – Adjustable 0.03 – 4.1 bar (0.5 – 60 PSI)

Mounting Style

FM – Flush Mount, MM – Manifold Mount, PM – Panel Mount, PT- Pipe Thread Mount

Port Connection

B80 – Ø2.65 mm barb for Ø1.6 mm I.D. tubing, B85 – Ø4.75 mm barb for Ø3.2 mm I.D. tubing, B86 – Ø5.60 mm barb for Ø4.3 mm I.D. tubing