Subminiature Vaccum Switch

The V-5100 Series Subminiature Vacuum Switches interface from vacuum to electrical control circuits; they are ideal for low differential vacuum applications.

Delivery time: 2 - 4 weeks
Contact us for shorter delivery times Art.-Nr.: N/A Categories: ,

The switches are adjustable 1 to 28″ Hg with a maximum signal pressure of 29.9″ Hg. The switches have three electrical terminals: Normally Open, Normally Closed and Common.
Four mounting styles are available: Flush Mount, Manifold Mount, Panel Mount, and Pipe Thread Mount. The Flush Mount has 0.125″ diameter mounting holes for mounting on a flat surface. The Manifold Mount is designed to mount directly on pneumatic circuit boards or manifold subplates; a Buna-N o-ring is supplied. The Panel Mount has a unique thread that goes from 1/8-27 tapered pipe thread to 1/8-27 straight pipe thread; a mounting nut is supplied. The Pipe Thread Mount has 1/8-27 tapered pipe threads.
The switches are provided with a B80 Barb, 10-32 UNF Barbed Fitting, for 1/16″ I.D.tubing unless otherwise requested.

FEATURES

  • Low Cost
  • Subminiature Size
  • Low Differential
  • Snap-Action Switch
  • Fast Response

SPECIFICATIONS

Electrical Specifications
Switch Action: Single pole, double throwd
Electrical Switch: UL and CSA Approved, (UL# E12252 N) (CSA File# LR 42370)
Electrical Connections: 0.187″ quick-connect terminal
Mechanical Specifications
Operating Speed: Activate or release in 25 milliseconds
Signal Pressure: 29.9″ Hg maximum
Adjustment Range: 1 to 28″ Hg
Temperature Limits: 5 to 48 °C (40 to 120 °F)

MATERIALS

Housing: Polysulfone
Diaphragm: Polyurethane
Spring: Stainless Steel or Music Wire

PORT CONNECTIONS

10-32 female threads, furnished with barbed fitting:
B80: 10-32 UNF Barbed Fitting for Ø1.6 mm (1/16″) I.D. tubing
B85: 10-32 UNF Barbed Fitting for Ø3.2 mm (1/8″) I.D. tubing
B86: 10-32 UNF Barbed Fitting for Ø4.3 mm (0.170″) I.D. tubing

MOUNTING

Flush Mount: 0.125″ diameter mounting hole; use No. 4 self-tapping or 5-40 screw
Manifold Mount: Two 0.125″ diameter mounting holes; use No. 4 self-tapping or 5-40 screw (A Buna-N o-ring is supplied)
Panel Mount: External 1/8-27 NPT to 1/8-27 NPS, internal threads are 10-32 UNF. Ø11.11 mm (7/16″) diameter mounting hole is required. (A mounting nut is supplied)
Pipe Thread Mount: 1/8-27 male tapered tapered pipe threads with 10-32 UNF internal threads

Adjustment Range

10 – Adjustable 2 – 10" Hg, 28 – Adjustable 3 – 28" Hg, 5 – Adjustable 1 – 5" Hg

Mounting Style

FM – Flush Mount, MM – Manifold Mount, PM – Panel Mount, PT- Pipe Thread Mount

Port Connection

B80 – Ø2.65 mm barb for Ø1.6 mm I.D. tubing, B85 – Ø4.75 mm barb for Ø3.2 mm I.D. tubing, B86 – Ø5.60 mm barb for Ø4.3 mm I.D. tubing

Switch Selection

.1B – 0.1 AMP, 10A – 10 AMP, 15A – 15 AMP, 25A – 25 AMP, 3A – 3 AMP, 5A – 5 AMP